SPON COMMUNICATIONS: BLAZING A TRAIL IN CUTTING-EDGE IP PA SYSTEM DESIGNS

SPON Communications: Blazing A Trail in Cutting-edge IP PA System Designs

SPON Communications: Blazing A Trail in Cutting-edge IP PA System Designs

Blog Article

Network PA System for medium to massive jobs



Intro


The XC-9000 system is a fully electronic network PA system based upon the TCP/IP protocol. By leveraging the TCP/IP procedure, the system makes certain the efficient and correct transmission of all data packages. Not just can it make use of existing local area network, such as LANs or the Net, to transmit program signals, but also it can also be deployed on a devoted broadcasting network.


A single-server system can support up to 3000 terminals and enables for server cascading. There are no constraints on the simultaneous program networks, accomplishing true full digital broadcasting.


System Features



Adaptable PA System Design


The PA system style is straightforward, consisting of service management software, network microphones, network amplifiers, network audio speakers, and various other devices.All equipment is attached using the TCP/IP intranet procedure, permitting adaptable setup and easy management of the system, with free control over program material, network devices, and areas with the network.


Ip SpeakerIp Speaker
Comprehensive Audio Management


The audio monitoring software application includes integrated functions for creating program strategies, flexible zoning, and pre-scheduled broadcasts.It sustains 24-hour shows, enabling for changing setups throughout all the time


Versatile Audio Source Assistance


The system supports numerous forms of audio resources for sending notices like live speech and BGM playback. Sound sources can originate from electronic musical applications, CD/DVD gamers, microphones, and so on. Additionally, the system gives diverse features of supporting numerous broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


Fire Alarm System Assimilation


The system has an emergency alarm function and can be integrated right into a fire alarm system. When the alarm system central system obtains the disconcerting signals, the cord will send the signal to devices, which triggers the XC-9000, sending out signals to audio speakers


Customers could select to pre-programmed settings to activate full-area or zoned alarms in emergency situations. The alarm system voices come in several kinds and can be edited catering to requirements. Customers can change language settings, upload and modify their audio resources according to specific needs, such as intruding alarm systems, fire alarm systems or air aid alarms, etc.


Emergency Alarm System Integration


The system has an emergency alarm feature and can be integrated right into a smoke alarm system. When the alarm system main system gets the alarming signals, the cable television will certainly transmit the signal to devices, which activates the XC-9000, sending out signals to audio speakers


Users can pick to pre-programmed setups to turn on full-area or zoned alarm systems in emergency situations. The alarm system voices been available in several types and could be edited catering to needs. Customers can transform language settings, upload and edit their audio resources according to specific demands, such as intruding alarms, fire alarms or air help alarms, etc.


Application Control for System Procedures


The system allows mobile app login and usage, permitting customers to start programs and other operations to authorized terminals through the web server software program, making certain a structured and practical experience.


Integrated SIP Compatibility


The system not just permits SIP phones to log in, but also can be connected to third-party SIP web server or IPPBX, which develops a totally incorporated and suitable communication system with seamless assimilation into existing systems.


Open up SDK


When huge task like smart park happens, the system supplies an open SDK integrated right into third-party application platforms - SPON Communications


System Facilities



Key Functions


Arranged Playback


The system is able to instantly broadcast according to the arranged jobs as long as individuals post the audio apply for each period of the day to the server and develop a playback schedule.


Area Broadcasting


The system can arbitrarily split a few network gadgets right into different areas to play specified audio programs or send out news to any assigned area. The quantity of each gadget can be remotely readjusted.


Real-time Broadcasting


The system can catch and broadcast radio programs or other exterior audio sources in real-time, and at the very same time broadcast them in sync.


Fire Alarm System Assimilation


The system can be integrated with the smoke alarm system for control. When a smoke alarm signal is caused, it automatically triggers the emergency situation program function and supports nearby flooring alarm systems. It also enables for hand-operated emergency situation broadcasting by clicking a single switch.


SIP Phone Assimilation


The system can be incorporated with SIP servers, allowing online speech of voice broadcasting by means of SIP phones to send out news anytime and anywhere.


CCTV Integration


The digital devices such as IP POE Speakers adopts the global basic have a peek at these guys ONVIF procedure, which allows their voices to be relayed via VMS platforms. The terminals can likewise be integrated with CCTV systems for integrated broadcast.


Key Products



Sound Monitoring Software XC-9000


B/S architecture, supports cross-platform applications.
Covers traditional broadcasting system functions, allowing for dividing monitoring.
Unified monitoring of terminals within the system, watching job standing, and batch volume adjustment, etc.
Supports structure multi-level web server designs, deploying administration according to individual geographical regions.
Offers SDK development packages for secondary development and integration with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Running Temperature: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Surface Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Operating Temperature level: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Frequency Response: 45Hz~ 18KHz.
Running Temperature level: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Feedback: 50Hz~ 20KHz.
Operating Temperature: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Action: 60Hz~ 18KHz.
Running Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.


Area Mixing Digital Amplifier NBS-2301


Power Supply : AC 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 that site ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP User Interface Device NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Procedure: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm outputs.
Running Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Service For Institution





Versatile Zoning Program:


The completely network terminals can recognize flexible zoning options, enabling broadcasting notifications to private terminals or different zones ( gadgets).


College Bell System:


It supplies school bell system at the beginning/ending of the class - IP PA System. Numerous circumstances can be developed, including various arranged broadcast jobs according to summer/winter timetable


Fire Alarm Integration


It sustains assimilation with smoke alarm systems, permitting emergency alarm signals to be integrated right into the PA system.


Classroom Sound Boosting


Terminals support day-to-day applications in class scenes. They can be connected to projectors or interactive whiteboard for audio boosting.


Ip Pa SystemIp Pa System

Smart Street Lamp/Security Post



Assistance SIP Procedure:


Integrated SIP procedure for seamless integration with network communication systems.


VMS Platforms Integration:


Integrated ONVIF method for assimilation with VMS platforms.


Third-Party Combination:


Constructed in HTTP API for integration with third event platforms.


Voice Alarm Activating:


Integrated in alarm input user interface for setting off voice alarm systems with cams.


Solution For Resort



Area Control by Floor:


The system uses full network settings, separating zones relying upon different floorings and control over each zone independently.


Fire Alarm Combination:


The system can be incorporated with smoke alarm system, enabling combination of smoke alarm signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable scheduled broadcasting, enabling adaptable arrangements according to different demands.


Emergency Broadcasting:


It supports emergency situation broadcasting for the whole area, allowing one-click emergency situation interaction.


Solution For Factory



Area Broadcasting:


It permits broadcasting to any area, assuring no disturbance between different areas.


Alarm Triggering:


Terminals have different type of user interfaces, making it possible for to trigger alarms when gotten in touch with cameras.


All Network Gadgets:


Implementation of completely network tools substantially click to investigate lowers the difficulty of operating such as checking devices on harmful sites, and therefore securing people and residential or commercial property.


The implementation of all network tools greatly decreases the problem of operation and upkeep administration


Integrated SIP Phones:


The system can be incorporated with SIP phone and program alerts using SIP phones any time and anywhere. Two-way audio talkback in between SIP phones and IP POE Audio speakers makes it simple for inspecting devices being in workplace or other offices.


The XC-9000 system is a totally digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system makes certain the effective and correct transmission of all information packages. The system supports numerous kinds of audio sources for sending alerts like online speech and BGM playback. In addition, the system provides varied functions of supporting numerous broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page